HLD for Shutdown and Startup Fabric module
Signed-off-by: mlok <marty.lok@nokia.com>
- Loading branch information
1 parent
389816a
commit 88063c1
Showing
1 changed file
with
66 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,66 @@ | ||
# PMON Enhancement -- Shutdown/Startup SFM module | ||
# High Level Design Document | ||
### Rev 1.0 | ||
- [About this Manual](#about-this-manual) | ||
- [Scope](#scope) | ||
- [Background](#background) | ||
- [1 Requirements Overview](#1-requirements-overview) | ||
* [1.1 Functional Requirements](#11-functional-requirements) | ||
- [2 Design Details](#2-design-details) | ||
* [2.1 Using the existing CLI command "sudo config chassis module shutdown/startup <module_name>" by modifying/enhancing the chassis_module.py](#21-using-the-existing-cli-command--sudo-config-chassis-module-shutdown-startup--module-name---by-modifying-enhancing-the-chassis-modulepy) | ||
* [2.2 Modify the vendor specified set_admin_state() in the module.py](#22-modify-the-vendor-specified-set-admin-state---in-the-modulepy) | ||
* [2.3 Modify the ModuleUpdater in chassisd.](#23-modify-the-moduleupdater-in-chassisd) | ||
- [3 Test Considerations](#3-test-considerations) | ||
- [4 References](#4-references) | ||
|
||
<small><i><a href='http://ecotrust-canada.github.io/markdown-toc/'>Table of contents generated with markdown-toc</a></i></small> | ||
###### Revision | ||
| Rev | Date | Author | Change Description | | ||
|:---:|:-----------:|:----------------------------------------------------------------------------------:|-----------------------------------| | ||
| 1.0 | 05/03/2024 | Marty Lok | Initial public version | | ||
|
||
# About this Manual | ||
This document describes the requirements for reset System Fabric Module (SFM) on a Chassis and the planned design/code changes for supporting this enhancement. | ||
|
||
# Scope | ||
This scope of this specification is using the existing module shutdown/startup commands and the modification supports resetting of the SFM Module | ||
|
||
# Background | ||
In order to avoid the crash of the Swss/Syncd processes of a SFM module, when a SFM module in a chassis is required to be reseated or hot swapped, a proper shutdown and startup procedure needs to be followed. | ||
|
||
|
||
# 1 Requirements Overview | ||
## 1.1 Functional Requirements | ||
This section describes the requirement for using existing CLI command shutdown/startup a SFM module on a Chassis system. | ||
1. Using the existing CLI command "sudo config chassis module shutdown/startup <module_name>" to shutdown/startup a SFM module | ||
2. Module remains down state if system is booting up with a configuration file which contains a module is set to down state | ||
|
||
# 2 Design Details | ||
The following changes are implementation and modification. | ||
## 2.1 Using the existing CLI command "sudo config chassis module shutdown/startup <module_name>" by modifying/enhancing the chassis_module.py | ||
1. Define and create a new method fabric_module_set_admin_status() with the following actions | ||
* Derive a list of ASIC number (asic_list) which is assoicated with this module_name from the CHASSIS_FABRIC_ASIC_TABLE in the CHASSIS_STATE_DB | ||
* For shutdown case: | ||
- Loop this asic_list and call the "systemctl stop" to stop the related swss@ and syncd@ services. | ||
- Delete the related CHASSIS_FABRIC_ASIC_TABLE entries in the CHASSIS_STATE_DB | ||
- Loop this asic_list and call the "systemctl start" to start the related swss@ and syncd@ service. | ||
* For startup case: | ||
- Loop the asic_list and call the "systemctl start" to start the related swss@ and syncd@ service | ||
2. Modify the existing shutdown_chassis_module() and startup_chassis_module() method to all the fabric_module_set_admin_status() | ||
* In order to avoid the raised condition of the chassisd re-populates CHASSIS_FABRIC_ASIC_TABLE entry while the shutdown command is executing, the implementation needs to make sure the new admin_status has been set to Redis DB before proceeds to stop related swss/syncd service and remove the CHASSIS_FABRIC_ASIC_TABLE entry. The get_config_module_state_timeout() function is introduced to verify the config value setting in Redis DB. | ||
|
||
## 2.2 Modify the vendor specified set_admin_state() in the module.py | ||
Modify the set_admin_state() in module.py for SFM module to shutdown/startup a SFM module. This function is already called by the existing ConfigManagerTask class which subscribes the CHASSIS_MODULE in the CONFIG_DB to shutdown/startup a module when user issues the CLI command "sudo config chassis module shutdown/startup <module_name>" on the Supervisor. | ||
|
||
## 2.3 Modify the ModuleUpdater in chassisd. | ||
Modify the ModuleUpdater class in chassisd to keep a SFM module in the down state when system is booting up with a configuration which contains a shutdown of a SMF module. | ||
1. Create and add a new fucntion get_module_admin_status() to get the admin_status from CHASSIS_CONFIG_TABLE in CONFIG_DB | ||
2. Modify the module_db_update() to call get_module_admin_status() to check the config module. If the module_cfg_status is not set to down, then populate the CH-TBDASSIS_FABRIC_ASIC_TABLE. Otherwise, just ignore it even the SFM module is present. This mechanism prevents the event is triggered in the swss.sh when admin_status is set to down state. | ||
|
||
# 3 Test Considerations | ||
UTs are also added to simulate the Fabric shutdown and startup | ||
|
||
# 4 References | ||
-TBD | ||
|
||
|